10
Thru-beam type: EX-11S□, parallel deviation diagram (typical)
CenterLeft
Right
Operating point ℓ(mm)
Sensing distance L (mm)
50 25 0 25 50
200
0
150
100
50
(
ℓ7
)
(
L7
)
<Installation interval for EX-11S□>
In case using at sensing distance (L7)
150mm, the operation point (ℓ7) is approx.
10.8mm according to diagram above.
The installation interval is
Approx. 10.8mm × 2 = approx. 21.6mm
Thus, install approx.21.6 or more away.
Emitter Receiver
EX-11S: approx. 21.6mm or more
150mm
EX-11S: approx. 21.6mm or more
Thru-beam type: EX-11SE□, parallel deviation diagram (typical)
50 25 0 25 50
200
0
150
100
50
(
L8
)
(
ℓ8
)
CenterLeft
Right
Operating point ℓ(mm)
Sensing distance L (mm)
<Installation interval for EX-11SE□>
In case using at sensing distance (L8)
150mm, the operation point (ℓ8) is approx.
6.2mm according to diagram above.
The installation interval is
Approx. 6.2mm × 2 = approx. 12.4mm
Thus, install approx.12.4 or more away.
EX-11SE: approx. 12.4mm or more
150mm
Emitter Receiver
EX-11SE: approx. 12.4mm or more