7.2.2 Functions Used and Restrictions
The maximum counting speed and pulse output frequency of the high-speed counter vary according to
the number of channels to be used or the combination of used functions. Use the chart below as a guide.
Simplified chart - Maximum counting speed of High-speed counter (For L14 and L30 types)
A: Available
Combination of high-speed counter
Max. counting speed (Frequency kHz)
Combination with pulse output function (trapezoidal control)
Single-phase
2-phase
No pulse output
Pulse output 1 CH
Pulse output 2 CH
CH0 CH1 CH2 CH3 CH0 CH2
Single-
phase
2-
phase
Single-
phase
2-
phase
Single-
phase
2-
phase
A
-
-
-
-
-
20
-
20
-
20
-
A A
-
-
-
-
20
-
20
-
20
-
A
A
A
-
-
-
20
-
20
-
14
-
A A A A
-
-
20
-
20
-
14
-
-
-
-
-
A
-
-
20
-
17
-
13
-
-
-
-
A A
-
20
-
16
-
12
-
-
A
-
A
-
20
20
20
17
20
13
-
-
A A A
-
20 20 20 17 20 13
A
-
-
-
-
A
20
20
20
16
20
12
A A
-
-
-
A 20 19 20 14 20 6
Note) The maximum counting speed may be lower than the above-mentioned values when the target value match
ON/OFF instruction (F166/F167) or an interrupt program is executed simultaneously.
Simplified chart - Maximum counting speed of High-speed counter (For L40 and L60 types)
Combination of high-speed counter
Max. counting speed (Frequency kHz)
Combination with pulse output function (trapezoidal control)
Single-phase
2-phase
No pulse output
Pulse output 1 CH
Pulse output 2 CH
CH0 CH1 CH2 CH3 CH0 CH2
Single-
phase
2-
phase
Single-
phase
2-
phase
Single-
phase
2-
phase
A
-
-
-
-
-
50
-
50
-
36
-
A
A
-
-
-
-
50
-
43
-
32
-
A A A
-
-
-
50
-
36
-
28
-
A
A
A
A
-
-
33
-
30
-
24
-
-
-
-
-
A
-
-
20
-
20
-
16
-
-
-
-
A
A
-
20
-
16
-
13
-
-
A
-
A
-
38 20 39 20 32 16
-
-
A
A
A
-
36
20
39
20
28
16
A
-
-
-
-
A 40 20 40 18 36 12
A
A
-
-
-
A
40
20
40
12
32
7
Note) The maximum counting speed may be lower than the above-mentioned values when the target value match
ON/OFF instruction (F166/F167) or an interrupt program is executed simultaneously.
Pulse input/output performance
Independent control
Single-phase
Max. output frequency (kHz)
CH0
CH1
For L14/L30 type
For L40/L60 type
A
-
20
50
A A 20 50
Note) The L14 type can only use CH0.
補間制御
Single-phase
Max. output frequency (kHz)
CH0
For L14/L30 type
For L40/L60 type
A
Not used
50