EasyManua.ls Logo

Panasonic FP3 - User Manual

Panasonic FP3
152 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
PROGRAMMABLE CONTROLLER
TechnicalManual
FP3/FP10S
MEWNET-TR (I/O) SYSTEM
FP3/5
MEWNET-TR(I/O) SYSTEM Technical Manual
ACG-M0076-1

Table of Contents

Questions and Answers

  • S
    Sarah MillerJul 27, 2025
    What to do if the COM. LED is flashing slowly on my Panasonic Controller?
    • A
      Ashley AndersonJul 27, 2025
      If the COM. LED on your Panasonic Controller is flashing slowly, it indicates that remote I/O control has been terminated due to a communications error or disconnection. Check the POWER LED and power supply wiring of the slave station. Also, inspect the wiring and look for any looseness of terminal screws, and verify the transmission cable for correct wiring.
  • R
    Robert WagnerJul 31, 2025
    Why is communication not possible with any slave station on my Panasonic Controller?
    • A
      Amy BellJul 31, 2025
      If communication is not possible with any slave station on your Panasonic Controller, it may be due to no power supply or a disconnection. Check that power is properly supplied to the slave stations and check the wiring between the master and slave stations.
  • M
    Mark ArmstrongAug 4, 2025
    What to do if the station monitor LED is OFF on my Panasonic Controller?
    • C
      Connie OlsonAug 4, 2025
      If the station monitor LED is OFF on your Panasonic Controller, it indicates no communications with the slave station since the system began operation. Make sure power is properly supplied to the slave station indicated by the unlit LED.
  • C
    Christopher HoustonAug 8, 2025
    Why is the station monitor LED flashing on my Panasonic Controller?
    • B
      Brian MccoyAug 8, 2025
      If the station monitor LED is flashing on your Panasonic Controller, it means communication is not possible with the slave station indicated by the flashing LED. Ensure power is properly supplied to the slave station indicated by the flashing LED.
  • B
    Bryan KingAug 13, 2025
    What to do if communication is not possible with some slave stations on my Panasonic Controller?
    • L
      Lisa MartinezAug 13, 2025
      If communication is not possible with some slave stations on your Panasonic Controller, check the wiring between the slave stations and ensure that power is properly supplied to slave station 1.
  • J
    jacqueline07Aug 17, 2025
    Why is the COM. LED ON on my Panasonic Controller?
    • R
      ricemaryAug 17, 2025
      If the COM. LED is ON on your Panasonic Controller, the system configuration is not set to 'remote I/O control enabled.' Set operation mode selector No. 1 to the OFF position, turn the power OFF and ON again.
  • M
    Michael StevensAug 22, 2025
    Why is the COM. LED OFF on my Panasonic Controller?
    • R
      ruizlauraAug 22, 2025
      If the COM. LED is OFF on your Panasonic Controller, it indicates that there is no communications with any slave station.

Summary

Chapter 1: System Configurations

1-1. System Configurations

Describes the FP3/FP10S MEWNET-TR system architecture and components.

1-2. Features

Details the key features of the MEWNET-TR system, including remote I/O and I/O link.

1-3. Product Types

Lists and describes master/slave station units and transmission cables.

1-4. Combinations

Explains system configurations and unit combinations.

Chapter 2: Specifications and Parts Terminology

2-1. Specifications

Provides general and system-specific technical specifications.

2-2. Master Station

Details the FP3 Transmitter Master Unit, including parts, operation modes, and specs.

2-3. Slave Stations

Describes FP I/O transmitter and expansion FP I/O terminal units.

Chapter 3: Installation and Wiring

3-1. Installation

Covers procedures and considerations for installing master and slave stations.

3-2. Wiring

Instructions for wiring power supplies, transmission cables, and I/O.

Chapter 4: Operation Mode Setting and I;O Allocation

4-1. Operation Mode Setting

Explains setting operating modes for master and slave stations.

4-2. I;O Allocation

Details I/O allocation, station number settings, and allocation tables.

Chapter 5: Before Trial Operation

5-1. Things to Check Before Turning the Power ON

Checklist for verifying installation and settings before system power-up.

5-2. Procedure Up to Trial Operation

Outlines steps for trial operation and initial checks.

Chapter 6: I;O Link Function

6-1. Master Station and Master Station

Describes I/O data exchange between two FP3/FP10S master stations.

6-2. FP-M;FP1 Master Station and FP3;FP10 S Master Station

Explains I/O data exchange between FP-M/FP1 and FP3/FP10S master stations.

6-3. I;O Link Application Examples

Provides practical examples of I/O link function applications.

Chapter 7: Troubleshooting

7-1. Checking the CPU When an Error Occurs

Guides on checking CPU status and diagnosing errors.

7-2. Remote I;O Control When an Error Occurs

Troubleshooting steps for errors in remote I/O control.

7-3. I;O Link Control When an Error Occurs

Troubleshooting steps for errors during I/O link control.

Chapter 8: Appendix

8-1. Specifications

Contains detailed specifications for system components.

8-2. Dimensions

Provides dimensional drawings for master, slave, and expansion units.

8-3. Settings

Details operation mode selectors and station number settings.

8-4. I;O Allocation Table

Tables showing I/O allocation patterns based on settings.

8-5. Transfer Time

Explains calculation and values for I/O response and transfer times.

8-6. Terminology

Defines technical terms used in the manual.

8-7. Product Types

Lists and categorizes all product types covered in the manual.

Panasonic FP3 Specifications

General IconGeneral
BrandPanasonic
ModelFP3
CategoryController
LanguageEnglish

Related product manuals