Loading...
Item
Add-
ress
Name
Default
value
Description
Controller input time constant settings
1 to 4
430
Controller input time
constant setting 1
X0 to X3
For L14/L30/L40/L60
1 ms
None
0.1ms
0.5ms
1 ms
2 ms
4 ms
8 ms
16 ms
32 ms
64 ms
431
Controller input time
constant setting 1
X4 to X7
For L14/L30/L40/L60
432
Controller input time
constant setting 2
X8 to XB
For L30/L40/L60
433
Controller input time
constant setting 2
XC to XF
For L30/L40/L60
434
Controller input time
constant setting 3
X10 to X13
For L40/L60
435
Controller input time
constant setting 3
X14 to X17
For L40/L60
436
Controller input time
constant setting 4
X18 to X1B
For L60
437
Controller input time
constant setting 4
X1C to X1F
For L60