34
KX-FT931LA-B
Note 1 - Standard facsimile units conforming to T.2 must have the following capability: Index of cooperation (IOC)=264.
Note 2 - Standard facsimile units conforming to T.3 must have the following capability: Index of cooperation (IOC)=264.
Note 3 - Standard facsimile units conforming to T.4 must have the following capability: Paper length=297 mm.
39 Reserved for future recording width capability.
40 Extend field Extend field
41 R8×15.4 lines/mm R8×15.4 lines/mm
42 300×300 pels/25.4 mm 300×300 pels/25.4 mm
43 R16×15.4 lines/mm and/or 400×400 pels/25.4 mm R16×15.4 lines/mm and/or 400×400 pels/25.4 mm
44 Inch based resolution preferred Resolution type selection
“0”: neritic based resolution
“1”: inch based resolution
45 Metric based resolution preferred Don’t care
46 Minimum scan line time capability for higher resolutions
“0”: T
15.4
= T
7.7
“1”: T
15.4
= 1/2T
7.7
Don’t care
47 Selective Polling capability Set to “0”.
48 Extend field Extend field
Signal Identification Signal Format Function
Training 1 ——————— A fixed pattern is transmitted to the receiving side at a speed (2400
bps to 9600 bps) designated by DCS, and the receiving side opti-
mizes the automatic equalizer, etc., according to this signal.
TCF
(Training Check)
——————— Sends 0 continuously for 1.5 seconds at the same speed as the
training signal.
CFR
(Confirmation to Receive)
X0100001 Notifies the sending side that TCF has been properly received. If
TCF is not properly received, FTT (Failure To Train) X0100010 is
relayed to the sender. The sender then reduces the transmission
speed by one stage and initiates training once again.
Training 2 ——————— Used for reconfirming the receiving side like training 1.
Image Signal Refer to the next page. ———————
RTC
(Return to Control)
——————— Sends 12 bits (0...01 × 6 times) to the receiver at the same speed as
the image signal and notifies completion of transmission of the first
sheet.
EOP
(End of Procedure)
X1110100 End of one communication
MCF
(Message Confirmation)
X0110001 End of 1 page reception
DCN
(Disconnect)
X1011111 Phase E starts.
MPS
(Multi-Page Signal)
X1110010 Completion of transmission of 1 page. If there are still more docu-
ments to be sent, they are output instead of EOP. After MCF recep-
tion, the sender transmits an image signal of the second sheet.
PRI-EOP
(Procedural Interrupt-EOP)
X1111100 If there is an operator call from the sender, it is output after RTC.
PIP
(Procedural Interrupt Positive)
X0110101 This is output when an operator call is received.
Bit No. DIS/DTC DCS