Loading...
4.4.2. Maximum Terminal Equipment
The following number of items of terminal equipment can be supported by the Hybrid IP-PBX.
Terminal Equipment Type Basic System 2-shelf System 3-shelf System 4-shelf System
Telephone
(using Digital XDP)
160
(240)*1
320
(480)*1
480
(720)*1
640
(960)*1
SLT 160 320 480 640
KX-T7600 series DPT 160 320 480 640
Other DPT 128 256 384 512
APT 80 160 240 320
IP-PT 160 320 480 640
DSS console 64
CS 32 64 96 128
PS (without an EMEC card) 256
PS (with an EMEC card) 512
Voice Processing System (VPS)*2 8
Doorphone 16 32 48 64
Door Opener 16 32 48 64
External Sensor 16 32 48 64
External Relay 16 32 48 64
Add-on Key Module 160 320 480 640
USB Module 160 320 480 640
*1 Even when Digital XDP is used, each shelf supports a maximum of 160 KX-T7600 series DPTs.
*2 Only a single VPS can be connected to one optional service card.
4.4.3. Power Supply Unit Selection for Each Shelf
The Hybrid IP-PBX needs a power supply unit (PSU) suitable for its configuration. For each shelf, calculate the load figure from
the type and number of items of equipment to be connected, and then determine the type of PSU that will be required.
Load Figure Calculation
Equipment Type Load Figure
PT KX-T7600 series DPT/KX-T7600
series DSS console
1
KX-T7560/KX-T7565 DPT 1
Other DPT/Other DSS console 4
APT 4
IP-PT 0
Extension Card *1 DHLC8 8
SLC8 8
ESLC16 16
EMSLC16 16
CS (1 unit) 4
PT-interface CS (1 unit) 4
ISDN Extension 2
VPS (1 port) 1
*1 Only the extension cards that can support SLTs count for the load figures.
PSU Capability
Each PSU supports a different load figure.
PSU Type Maximum Load Figure
PSU-M 128
PSU-L 512
If the total load figure is greater than 128, you must install the PSU-L. If the total load figure is less than 128, but you expect