11.1.1.7. Framer IC Error Detection Diagnosis
Diagnostic the feature to detect the alarm signal of Framer IC is operating correctly.
Diagnosis point
Bipolar violation error Bipolar violation error detection test
CRC error CRC error detection test
Framing error Framing error detection test
Primary circuit Primary circuit error detection test
Diagnosis result
OK DSP DTMF generator/receiver diagnosis OK
NG DSP DTMF generator/receiver diagnosis NG
11.1.1.8. CSIF Loop Back Diagnosis
Diagnostic by Loop back test to CSIF
CS-INF loop back diagnosis test channel
Dch port xx D channel Port No. xx test
Bch port xx B channel Port No. xx test
Diagnosis point
DNIC analog DNIC analog loop back test
DNIC digital DNIC digital loop back test
Diagnosis result
OK CS-INF loop back diagnosis OK
NG CS-INF loop back diagnosis NG
11.1.1.9. Super Frame Synchronization Diagnosis
Diagnostic Super frame synchronization feature of the CSIF card.
Diagnosis point
DECT DECT super frame synchronization test
SS SS super frame synchronization test
Diagnosis result
OK Super frame synchronization diagnosis OK
NG Super frame synchronization diagnosis NG
65