33
KX-TG8041RU/KX-TGA800RU
9.1.4.3. Check Table for RF part
Note:
(*1) Refer to Adjustment Standard (Base Unit) (P.51)
(*2) Refer to Adjustment Standard (Handset) (P.55)
No. Item BU (Base Unit) Check HS (Handset) Check
1 Link Confirmation Normal
HS, BU Mode: [Normal mode]
1. Register Regular HS to BU (to be
checked).
2. Press [Talk] key of the Regular HS to
establish link.
1. Register HS (to be checked) to Regular
BU.
2. Press [Talk] key of the HS to establish link.
2 X’tal Frequency confirmation 1. Check X’tal Frequency. (*1)
(10.368 MHz ± 100 Hz)
1. Check X’tal Frequency. (*2)
(10.368 MHz ±100 Hz)
3 Range Confirmation Normal
HS, BU Mode: [Normal mode]
1. Register Regular HS to BU (to be
checked).
2. Press [Talk] key of the Regular HS to
establish link.
3. Compare the range of the BU (being
checked) with that of the Regular BU.
1. Register HS (to be checked) to Regular
BU.
2. Press [Talk] key of the HS to establish link.
3. Compare the range of the HS (being
checked) with that of the Regular HS.