42
KX-TG8041RU/KX-TGA800RU
(K)* Frequency Offset Confir-
mation
- Follow steps 1 to 3 of (I).
4.Confirm that the frequency Offset is < ± 20 kHz.
IC1,
R801~R806,
C808~C814,
C819, C825,
C834, IC801,
L802~L804,
D801, R807,
L801, C820,
C822, C826,
C827, C832,
C833, C837,
D802, DA1,
C117, C124,
C186, C187,
C802~C804,
R107, R108
(L)* Frequency Drift Confir-
mation
- Follow steps 1 to 3 of (I).
4.Confirm that the frequency Drift is < ± 30KHz/msec.
IC1,
R801~R806,
C808~C814,
C819, C825,
C834, IC801,
L802~L804,
D801, R807,
L801, C820,
C822, C826,
C827, C832,
C833, C837,
D802, DA1,
C117, C124,
C186, C187,
C802~C804,
R107, R108
(M)* Sensitivity Receiver
Confirmation
- Follow steps 1 to 3 of (I).
4.Set DECT tester power to -88 dBm.
5.Confirm that the BER is < 1000 ppm.
IC1,
R801~R806,
C808~C814,
C819, C825,
C834, IC801,
L802~L804,
D801, R807,
L801, C820,
C822, C826,
C827, C832,
C833, C837,
D802, DA1,
C117, C124,
C186, C187,
C802~C804,
R107, R108
(N)* Power RAMP Confirma-
tion
- Follow steps 1 to 3 of (I).
4.Confirm that Power RAMP is matching.
IC1,
R801~R806,
C808~C814,
C819, C825,
C834, IC801,
L802~L804,
D801, R807,
L801, C820,
C822, C826,
C827, C832,
C833, C837,
D802, DA1,
C117, C124,
C186, C187,
C802~C804,
R107, R108
Items Check
Point
Procedure Check or
Replace Parts