43
KX-TG8105RU/KX-TG8106RU/KX-TGA810RU
(H)* DTMF Generator Check - 1. Connect CN1 (Telephone Socket) to DTMF tester. (Road=600 )
2. Link Handset and push dial key.
3. Confirm DTMF character.
4. Confirm that the high Group is -3 ± 2dBm.
5. Confirm that the low Group is -6 ± 2dBm.
IC7, R67, IC6,
R116, C141,
R29, C22, C23,
R18~R24,
C14~C17, Q5,
D4
(I)* Transmitted Power Con-
firmation
- Remove the Antenna before starting step from 1 to 7.
1. Configure the DECT tester (CMD60) as follows;
<Setting>
Short A_1 and GND.
Test mode: FP
Traffic Carrier: 5
Traffic Slot: 4
Mode: Loopback
PMID: 00000
RF LEVEL = -70dBm.
2. Execute the command “testmode”.
3. Execute the command “sendchar dmv 2 2”.
4. Check that “Signalling Status” has been set to “Locked”, then press “ACCEPT
RFPI”.
5. Initiate connection from Dect tester (“set up connect”)
6. Execute the command “ANT1”.
7. Confirm that the NTP value at ANT is 20dBm ~ 25dBm.
IC7, IC10, L7,
L3, L4, L6,
C117, C118,
C119, C120,
C124, C125,
R106, R109,
DA1, C102,
R102, R103,
Q10, C110,
C112, R111,
C126, C127,
R112
(J) Modulation Check and
Adjustment
- Follow steps 1 to 6 of (I).
7.Confirm that the B-Field Modulation is -350 ~ -400/+320 ~ +370kHz/div using
data type Fig31.
8.Adjust the B-Field Modulation if required. (Execute the command “readmod”
and “wrtmod xx”, where xx is the value.)
IC7, IC10, L7,
L3, L4, L6,
C117, C118,
C119, C120,
C124, C125,
R106, R109,
DA1, C102,
R102, R103,
Q10, C110,
C112, R111,
C126, C127,
R112
(K) Frequency Offset Check - Follow steps 1 to 6 of (I).
7.Confirm that the frequency offset is < ± 45kHz.
IC7, IC10, L7,
L3, L4, L6,
C117, C118,
C119, C120,
C124, C125,
R106, R109,
DA1, C102,
R102, R103,
Q10, C110,
C112, R111,
C126, C127,
R112
(L) Frequency Dirft Confir-
mation
- Follow steps 1 to 6 of (I).
7.Confirm that the frequency drift is < ± 30kHz/ms.
IC7, IC10, L7,
L3, L4, L6,
C117, C118,
C119, C120,
C124, C125,
R106, R109,
DA1, C102,
R102, R103,
Q10, C110,
C112, R111,
C126, C127,
R112
(M) Sensitivity Receiver
Confirmation
- Follow steps 1 to 6 of (I).
7.Set DECT tester power to -90dBm.
8.Confirm that the BER is < 1000ppm.
IC7, IC10, L7,
L3, L4, L6,
C117, C118,
C119, C120,
C124, C125,
R106, R109,
DA1, C102,
R102, R103,
Q10, C110,
C112, R111,
C126, C127,
R112