KX-TG8105RU/KX-TG8106RU/KX-TGA810RU
11.6. Things to Do after Replacing IC
Cautions:
Some of the content on this page may not apply to models from some countries. The contents below are the minimum adjust-
ments required for operation.
11.6.1. Base Unit
Before making the following adjustment, ensure you have carried out PC Setting (P.55) in The Setting Method of JIG (Base
Unit).
Note:
(*1) XX: country code, YY: revision number
“XX” and “YY” vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in JIG and PC
(P.55).
(*2) Refer to Check Point (Base Unit) (P.42)
11.6.2. Handset
Before making the following adjustment, ensure you have carried out PC Setting (P.59) in The Setting Method of JIG (Hand-
set).
Note:
(*3) XX: country code, YY: revision number
“XX” and “YY” vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in JIG and PC
(P.59).
(*4) Refer to Check Point (Handset) (P.46)
IC Necessary Adjustment
BBIC
(IC7)
Programs for Voice processing, interface for RF and
EEPROM
1. Default batch file: Execute the command “default.bat”.
2. Country version batch file: Execute the command
“TG8100XXrevYY.bat”. (*1)
3. Clock adjustment: Refer to Check Point (F). (*2)
EEPROM
(IC5)
Adjustment parameter data
(country version batch file, default batch file, etc.)
1. Change the address “0000” of EEPROM to “AA”.
2. Default batch file: Execute the command “default.bat”.
3. Country version batch file: Execute the command
“TG8100XXrevYY.bat”. (*1)
4. Clock adjustment: Refer to Check Point (F). (*2)
IC Necessary Adjustment
BBIC
(IC1)
Programs for Voice processing, interface for RF and
EEPROM
1. Default batch file: Execute the command “default.bat”.
2. Default batch file (remaining); Execute the command
“TGA810DEFrevYY.bat”. (*3)
3. Country version batch file: Execute the command
“TGA810XXrevYY”. (*3)
4. Clock adjustment: Refer to Check Point (J). (*4)
5. 1.8 V setting and battery low detection: Refer to Check
Point (A), (H) and (I). (*4)
EEPROM
(IC3)
Adjustment parameter data
(country version batch file, default batch file, etc.)
1. Change the address “0015” of EEPROM to “55”.
2. Default batch file: Execute the command “default.bat”.
3. Default batch file (remaining); Execute the command
“TGA810DEFrevYY.bat”. (*3)
4. Country version batch file: Execute the command
“TGA810XXrevYY”. (*3)
5. Clock adjustment: Refer to Check Point (J). (*4)
6. 1.8 V setting and battery low detection: Refer to Check
Point (A), (H) and (I). (*4)