KX-TG9471B/KX-TG9472B/KX-TGA939T
11 Measurements and Adjustments
This chapter explains the measuring equipment, the JIG connection, and the PC setting method necessary for the
measurement in Troubleshooting Guide (P.27)
11.1. Equipment Required
DECT tester: Rohde & Schwarz, CMD 60 is recommended.
Frequency counter: It must be precise enough to measure intervals of 1 Hz (precision; ±4 ppm).
Hewlett Packard, 53131A is recommended.
Digital multi-meter (DMM): it must be able to measure voltage and current.
Oscilloscope
11.2. The Setting Method of JIG
<Preparation>
Serial JIG cable: PQZZ1CD300E*
PC which runs in DOS mode
Batch file CD-ROM for setting: PNZZTG9471B
Note:
*: If you have the JIG Cable for TCD500 series
(PQZZ1CD505E), change the following values of
resistance. Then you can use it as a JIG Cable for both
TCD300 and TCD500 series. (It is an upper compatible JIG
Cable.)
Note:
*: If you have the JIG Cable for TCD500 series
11.2.1. Connections (Base Unit)
Connect the AC adaptor to DC-JACK (base unit).
Connect the JIG Cable GND (black) to GND.
Connect the JIG Cable RX (red) to URX and TX (yellow) to UTX.
Note:
*: COM port names may vary depending on what your PC calls it.
Resistor Old value (k)New value (k)
R2 22 3.3
R3 22 3.3
R4 22 4.7
R7 4.7 10
Base unit P. C. board
UTX (yellow)
AC adaptor
1
3
2
3
GND (black)
URX (Red)
To Serial Port
(COM port 1*)
JIG Cable
PC
URX
UTX
GND