110
⿎
Logo le : CDF
Sets the logo le.
• Setting / Readout data of logo marking function
STX CDF
Sub
command
[Log No.] [Log le name]
Variable length
(Check sum) Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
• Readout request of logo marking function
STX CDF R
[Logo No.]
2-byte
(Check sum) Delimiter
Name Data length [byte] Description Remarks
Logo No. 2 “00”–“15”
Logo le name Variable length
The long le name can be
specied. Except the extended
characters, entry of up to 10 shift-
JIS characters or 20 ASCII code
characters is recommended.
The logo le name corresponding to the
specied number is indicated.
The logo le setting will be deleted when no
le name is specied in this command.
• For VEC le, the extension can be
omitted (in this case, the response has
an extension.)
When the le name is “ABCD.VEC”:
“ABCD” or “ABCD.VEC”
• For a DXF le, an extension is required.
When the le name is “ABCD.DXF”:
“ABCD.DXF”.
Reference
• In the case of specifying logo le in VEC format, apply CDC command for setting logo condition, and in the case of
specifying logo le in DXF format, apply CDD command for setting logo condition.
• If readout data includes characters that cannot be expressed in ASCII code such as Katakana and Kanji (2-byte
character), these 2-byte characters are read out in shift-JIS code.