129
⿎
Laser power : LPW
Sets the laser power.
• Setting / Readout data of laser power
STX LPW
Sub
command
[Laser power]
5-byte
(Check
sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
• Readout request of laser power
STX LPW R (Check sum) Delimiter
Name
Data
length
[byte]
Description Remarks
Laser power 5
“000.5”–“100.0”
(Set by increment of 0.5)
⿎
Scan speed : SSP
Sets the scan speed of the laser.
• Setting / Readout data of scan speed
STX SSP
Sub
command
[Scan speed]
5-byte
(Check
sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
• Readout request of scan speed
STX SSP R (Check sum) Delimiter
Name
Data
length
[byte]
Description Remarks
Scan speed 5
Model type* Setting range [mm/sec.]
LP-V10/LP-V15
“00001”–“12000”
LP-4x0/LP-4x5
LP-4x1/LP-W “00001”–“06000”
* For the detail of the model type, refer to “Target laser marker” (P.8).