EasyManua.ls Logo

Panasonic MBDL*25 Series - Connector and Terminal Block Configuration; Power Connector and Terminal Block (Sizes A, B)

Panasonic MBDL*25 Series
69 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No. SX-DSV03015 - 11 -
Motor Business Unit, Panasonic Corporation
6. Configuration of connectors and terminal blocks
6-1 Power connector XA , XB , XC , XD and terminal block
[1] Size A, B of 100 V and 200 V system
Connector
pin No.
Terminal
symbol
Name Description
XA
5 L1
Main power
supply input
100 V
Single phase 100-120 V
+ 10 %
50/60 Hz input
- 15 %
Use L1 and L3 terminal for single phase input
4 L2
200 V
Single or 3 phase 200-240 V
+ 10 %
50/60 Hz input
- 15 %
3 L3 Use L1 and L3 terminal for single phase input
2 L1C
Control power
supply input
100 V Single phase 100-120 V
+ 10 %
50/60 Hz input
- 15 %
1 L2C 200 V Single phase 200-240 V
+ 10 %
50/60 Hz input
- 15 %
XB
6 P
Regen resistor
connection
When a trip happens due to a regenerative load protection error, connect
an external regenerative resistor (prepared by customer) between P and
B.
Then, specify the external regenerative resistor for the parameter
Pr0.16.
Do not connect N terminal.
5 N
4 B
3
U
Motor connection
Connect each phase of the motor winding.
U: U phase V: V phase W: W phase
2
V
1
W
Earth
Earth terminal for grounding
* Tighten the earth screws M4 with the 0.7-0.8 Nm torque respectively.

Related product manuals