4.3. Fan Control
While compressor is running, evaporator fan is running.
When compressor stops and if damper motor is closed 2min run - 2 min stop operation starts and continue until compressor runs
or damper motor opens again.
If ambient temperature is ATC ≤ 22 °C or ATC ≥ 30 °C
• While compressor is running, evaporator fan motor is running.
• If PCC sensor is warmer than damper on set values damper must be on and fan motor must work continiously untill PCC sensor
reach to damper close set values.
• If PCC sensor is colder than damper close set values damper must be off and if compressor is stopping fan also must be off.