4. Pull multiflow styrofoam slightly from the left side.
5. Take out the putty from the socket housing.
Note: Keep putty for re-sealing the connectors after
replacement.
6. Take out the sockets and replace the PCC sensor & Multi-
flow group.
Reseal the putty and place the styrofoam into its place,
also place the PCC sensor to its holder at cover and close
the cover. Then fix the screws and place the caps.
10.4. Replacement of PC Bottom
Multiflow
(including the dumper motor)
1. First Remove the crispers, crisper shelf,chiller cover and
chiller.