48
After welding process mount the fan motor box and
make its connections with U-CONNECTOR as told in
Fan Motor replacement
section.
8. Re-connect all the connections and re-seal the housing
with putty. Tie the cables with cable tie and close the air-
flow cover. (as told in previous sections)
10.9. Replacement of Fin Evapora-
tor (only)
1. First remove the airflow cover, take out the fan connec-
tors, cut off the fan connections (black cables) and
remove the fan motor box from its place as told in [Fan
motor Replacement] section before.
Note: To disconnect the connectors pull them to the
down to release the tabs on connectors.
Warning: This process needs gas defla-
tion, gas re-charging and welding pro-
cesses so its need to be done by trained
professionals.
Instructions of gas deflation, gas re-charg-
ing and welding processes will be given at
appendix as a separate presentation.
Warning: This process needs gas defla-
tion, gas re-charging and welding pro-
cesses so its need to be done by trained
professionals.
Instructions of gas deflation, gas re-charg-
ing and welding processes will be given at
appendix as a separate presentation.
Warning: Make sure the unit is unplugged.