4. Remove the evaporator by pulling forward in a horizontal
direction. Do not push it up or down. You may broke the
fixing plastics.
Warning: Operator should certainly wear gloves dur-
ing evap replacement.
5. Place the new Evaporator Assy. to its place, when fixing
the Evaporator Assy. press it horizontally otherwise you
might damage the fixing plastics.
6. Weld the pipes with oxygen welding.
Note: You need to protect the plastic cabinet from the
fire of welding with a protector as shown in the below
pictures.
7. Seal the welding point with bitumen (after they cooled
down) and tie with cable tie.