76
11.1.3. Display
Being used in electronic No-frost models. PC & FC settings,
menu & service mode and other settings are being adjusted
with display buttons. All settings can be seen via display
screen.
Possible Main PCB defects:
Socket connection fault
Damage on main PCB due to high voltage
Relay contact fault on main PCB
Display button fault
Wavy display screen
11.1.4. Inverter
Being used to control and adjust compressor working fre-
quency also controls the LED inner lightning at product.
11.1.5. Defrost Heater:
Being used to defrost the icing formations.
11.1.6. Thermal fuse:
Being used in all no-frost models and placed on the right side of
fin evaporator. Defrosting will be terminated by DFC. In case of
faulty DFC, thermal fuse will switch off the circuit at +76 °C.