4. Remove the evaporator by pulling forward in a horizontal
direction. Do not push it up or down. You may broke the
fixing plastics.
Warning: Operator should certainly wear gloves dur-
ing heater replacement.
5. Cut the cable ties around the evaporator and sensors.
6. Remove the tape around defrost sensor and keep the
tape for re-sealing.
Remove the defrost sensor and thermal fuse.