If the surface of projection polarizer is caught,
it might be damaged.
Must catch the edge of projection polarizer
with tweezers.
c. Press the adhesive part and secure the projection
polarizer.
7.17. Replacement of PBS Array
(Analysis Block)
1. Remove the analysis case (upper) according to the steps 1
through 3 in the section 7.15. "Replacement of Incidence
Polarizer (R and B)".
2. Remove the PBS array.
3. Install new PBS array.
Note:
·
Be careful not to mistake the direction (inside and
outside, upper and lower).
·
Be careful not to touch the surface of PBS array.
20
PT-LB80NTU / PT-LB80NTE / PT-LB80NTEA / PT-LB80U / PT-LB80E / PT-LB80EA / PT-LB75NTU / PT-LB75NTE / PT-LB75NTEA / PT-LB75U / PT-LB75E / PT-LB75EA