Maintenance/replacement
56
- ENGLISH
Maintenance
Note
The usage period of
z
3 000 hours
/ 4
000 hours
/ 4 500 hours / 5 000 hours is a rough estimate and is not guaranteed.
Used for PT-LX351U
z
The used lamp time is calculated internally in the following formula as the used time in each setting of [Normal], [Auto],
[ECO1] and [ECO2] in [Lamp power mode]:
Lamp runtime = (Lamp runtime of [Normal] × 60 + Lamp runtime of [Auto] × 24 + Lamp runtime of [ECO1] or [ECO2] × 45)
÷ 60
In order to estimate the lamp life, please refer to [Lamp Hours Used (Normal)] and [Lamp Hours used (ECO)] in
the [Lamp settings] menu (
Æ
page 43). [Lamp Hours Used (ECO)] is a total real time under [Auto], [ECO1] and
[ECO2] lamp power modes. Please note that they are not displayed individually.
Lamp use time = ([Lamp Hours Used (Normal)] × 60 + [Lamp Hours Used (ECO)] ×
α
1
) ÷ 60
When setting under both [Normal] and [ECO1]/[ECO2], not using [Auto]:
α
1
= 45
When setting under both [Normal] and [Auto], not using [ECO1]/[ECO2]:
α
1
= 24
When setting under both [ECO1]/[ECO2] and [Auto]: 24
<
α
1
<
45
The ratio of
α
1
will be smaller if the used time of [Auto] is more than that of [ECO1]/[ECO2].
Used for PT-LX321U
z
The used lamp time is calculated internally in the following formula as the used time in each setting of [Normal], [Auto] and
[ECO] in [Lamp power mode]:
Lamp runtime = (Lamp runtime of [Normal] × 51 + Lamp runtime of [Auto] × 24 + Lamp runtime of [ECO] × 34) ÷ 51
In order to estimate the lamp life, please refer to [Lamp Hours Used (Normal)] and [Lamp Hours used (ECO)] in
the [Lamp settings] menu (
Æ
page 43). [Lamp Hours Used (ECO)] is a total real time under [Auto] and [ECO]
lamp power modes. Please note that they are not displayed individually.
Lamp use time = ([Lamp Hours Used (Normal)] × 51 + [Lamp Hours Used (ECO)] ×
α
2
) ÷ 51
When setting under both [Normal] and [ECO], not using [Auto]:
α
2
= 34
When setting under both [Normal] and [Auto], not using [ECO]:
α
2
= 24
When setting under both [ECO] and [Auto]: 24
<
α
2
<
34
The ratio of
α
2
will be smaller if the used time of [Auto] is more than that of [ECO].
Used for PT-LW271U / PT-LX271U
z
The used lamp time is calculated internally in the following formula as the used time in each setting of [Normal], [Auto] and
[ECO] in [Lamp power mode]:
Lamp runtime = (Lamp runtime of [Normal] × 60 + Lamp runtime of [Auto] × 30 + Lamp runtime of [ECO] × 50) ÷ 60
In order to estimate the lamp life, please refer to [Lamp Hours Used (Normal)] and [Lamp Hours used (ECO)] in
the [Lamp settings] menu (
Æ
page 43). [Lamp Hours Used (ECO)] is a total real time under [Auto] and [ECO]
lamp power modes. Please note that they are not displayed individually.
Lamp use time = ([Lamp Hours Used (Normal)] × 60 + [Lamp Hours Used (ECO)] ×
α
3
) ÷ 60
When setting under both [Normal] and [ECO], not using [Auto]:
α
3
= 50
When setting under both [Normal] and [Auto], not using [ECO]:
α
3
= 30
When setting under both [ECO] and [Auto]: 30
<
α
3
<
50
The ratio of
α
3
will be smaller if the used time of [Auto] is more than that of [ECO].
Used for PT-LW321U
z
The used lamp time is calculated internally in the following formula as the used time in each setting of [Normal], [Auto] and
[ECO] in [Lamp power mode]:
Lamp runtime = (Lamp runtime of [Normal] × 60 + Lamp runtime of [Auto] × 27 + Lamp runtime of [ECO] × 45) ÷ 60
In order to estimate the lamp life, please refer to [Lamp Hours Used (Normal)] and [Lamp Hours used (ECO)] in
the [Lamp settings] menu (
Æ
page 43). [Lamp Hours Used (ECO)] is a total real time under [Auto] and [ECO]
lamp power modes. Please note that they are not displayed individually.
Lamp use time = ([Lamp Hours Used (Normal)] × 60 + [Lamp Hours Used (ECO)] ×
α
4
) ÷ 60
When setting under both [Normal] and [ECO], not using [Auto]:
α
4
= 45
When setting under both [Normal] and [Auto], not using [ECO]:
α
4
= 27
When setting under both [ECO] and [Auto]: 27
<
α
4
<
45
The ratio of
α
4
will be smaller if the used time of [Auto] is more than that of [ECO].