Chapter 7āAppendix ā Technical information
ENGLISH - 253
r LENS H SHIFT, LENS V SHIFT, LENS FOCUS, LENS ZOOM
Performance Parameter Default value
Lens adjustment
(
-
) High speed 0-31
128
(
-
) Low speed 32-63
(
-
) Fine adjustment 64-95
Operation stop 96-159
Lens adjustment
(+) Fine adjustment 160-191
(+) Low speed 192-223
(+) High speed 224-255
r LENS FUNCTION SELECT (when [Art-Net CHANNEL SETTING] is set to [1])
Operate together with LENS CONTROL.
Performance Parameter Default value
No operation 0-15
0
LENS H SHIFT 16-31
LENS V SHIFT 32-47
LENS FOCUS 48-63
LENS ZOOM 64-79
Move to the home position 80-95
Load LENS MEMORY1 96-111
Load LENS MEMORY2 112-127
Load LENS MEMORY3 128-143
No operation 144-255
r LENS CONTROL (when [Art-Net CHANNEL SETTING] is set to [1])
Operate together with LENS FUNCTION SELECT.
Performance Parameter Default value
Lens adjustment
(
-
) High speed 0-31
127
(
-
) Low speed 32-63
(
-
) Fine adjustment 64-95
Operation stop 96-127
Lens adjustment
(+) Fine adjustment 128-159
(+) Low speed 160-191
(+) High speed 192-223
Execute command action 224-255
r POWER
Performance Parameter Default value
Standby 0-63
0No operation 64-191
Power on 192-255
r SHUTTER
Performance Parameter Default value
SHUTTER: Opened 0-63
128No operation 64-191
SHUTTER: Closed 192-255