Chapter 3 Basic Operations — Switching on/off the projector
58 - ENGLISH
6) Press qw to adjust.
Operation
Adjustment
Range of adjustment
Brightness Runtime (estimate)
Press w.
The screen becomes brighter. The runtime becomes shorter.
8.0 % - 100.0 %
Press q.
The screen becomes darker. The runtime becomes longer.
7) Press as to select [CONSTANT MODE].
8) Press qw to switch the item.
f The items will switch each time you press the button.
[OFF] Does not perform the brightness control (correction by the brightness sensor).
[AUTO]
Performs the brightness control (correction by the brightness sensor).
When the brightness of light source or white balance changes, the brightness of the screen is
automatically corrected.
[PC]
Synchronizes nine or more projectors using a computer and the dedicated software “Multi Monitoring
& Control Software”
*1
.
*1 “Multi Monitoring & Control Software” is included in the supplied CD-ROM.
f When not performing the brightness control ([OFF] is selected), proceed to Step 15).
f When [PC] is selected, proceed to Step 11).
9) Press as to select [LINK].
10) Press qw to switch the item.
f The items will switch each time you press the button.
[OFF]
Performs correction by the brightness sensor on one projector without synchronizing with the other
projectors.
The duration that the constant brightness is kept will become longer by setting the value of [LIGHT
OUTPUT] smaller.
[GROUP A]
[GROUP B]
[GROUP C]
[GROUP D]
Performs correction by the brightness sensor in multiple projectors in synchronization.
Up to four groups (A to D) can be set within the same subnet by using the network function.
You can register and synchronize up to eight projectors in one group.
11) Press as to select [CALIBRATION TIME].
12) Press the number (<0> - <9>) buttons on the remote control to enter the time.
f The projector is in the adjustment mode (the time is blinking).
f Press qw to select “hour” or “minute”.
f [CALIBRATION TIME] is set when the cursor is moved from [CALIBRATION TIME] using as.
f Brightness and color are measured at the specied time. The dynamic contrast function does not operate
during measurement.
f When the time is not to be specied, press the <DEFAULT> button while [CALIBRATION TIME] is selected
(the time is not blinking) using as.
13) Press as to select [CALIBRATION MESSAGE].
14) Press qw to switch the item.
f The items will switch each time you press the button.
[ON] Displays the message during calibration.
[OFF] Does not display the message during calibration.
15) Press the <ENTER> button to proceed to the initial setting.