Chapter 4Settings — [PROJECTOR SETUP] menu
ENGLISH - 123
4) Press qw to switch the item.
f The items will switch each time you press the button.
[OFF] Does not correct the brightness of the screen by the brightness sensor.
[AUTO]
Corrects the brightness of the screen by the brightness sensor.
When the brightness of light source or white balance changes, the brightness of the screen is
automatically corrected.
[PC]
Synchronizes nine or more projectors using a computer and the dedicated software “Multi Monitoring
& Control Software”
*1
.
*1 “Multi Monitoring & Control Software” is included in the supplied CD-ROM.
f Proceed to Step 7) when [PC] is selected.
5) Press as to select [LINK].
6) Press qw to switch the item.
f The items will switch each time you press the button.
[OFF]
Performs correction by the brightness sensor on one projector without synchronizing with the other
projectors.
The duration that the constant brightness is kept will become longer by setting the value of [LIGHT
OUTPUT] smaller.
[GROUP A]
[GROUP B]
[GROUP C]
[GROUP D]
Performs correction by the brightness sensor in multiple projectors in synchronization.
Up to four groups (A to D) can be set within the same subnet by using the network function.
Up to eight projectors can be registered and synchronized in one group.
7) Press as to select [CALIBRATION TIME].
8) Press the <ENTER> button.
f The projector will go into the adjustment mode (the time is blinking).
9) Press qw to select “hour” or “minute”, and press as or the number (<0> - <9>) buttons to set a
time.
f Selecting “hour” allows setting of only the hour in increments of one hour, and selecting “minute” allows
setting of only the minute in increments of one minute between 00 and 59.
f When the time is not specied, select [OFF] between 23 and 00 of the hour, or between 59 and 00 of the
minute.
10) Press the <ENTER> button.
f [CALIBRATION TIME] is set.
f Brightness and color are measured at the specied time. The dynamic contrast function does not operate
during measurement.
11) Press as to select [CALIBRATION MESSAGE].
12) Press qw to switch the item.
f The items will switch each time you press the button.
[ON] Displays message during calibration.
[OFF] Does not display messages during calibration.
13) Press as to select [APPLY].
14) Press the <ENTER> button.
f When [CONSTANT MODE] in [BRIGHTNESS CONTROL SETUP] is set to anything other than [OFF], the
brightness and white balance of light source at the time when the <ENTER> button is pressed is recorded
as the standard brightness and white balance.
f If the <ENTER> button is pressed when [LINK] is set from [GROUP A] to [GROUP D], the group name is
displayed on the screens of projectors that have been set in the same group.
LINK GROUP A
15) When the confirmation screen is displayed, press qw to select [OK], and press the <ENTER> button.