114 - ENGLISH
1) Remove the air filter cover. (Fig.1)
f Pull out the air lter cover from the hook of the projector while slightly pushing upward the tabs of the air
lter cover and open it in the direction of the arrow in gure.
2) Remove the air filter unit.
f The air lter unit is xed by the three hooks. Grasp the bre of the air lter unit near to the cover side with
one hook and then pull the air lter unit out from the air lter cover as arrow direction shown. (Fig.2)
f After removing the air lter unit, remove foreign objects and dust from the air lter compartment and the
projector’s intake vent if there are any.
Cleaning the air lter unit
Remove the air lter unit beforehand according to the previously described procedure in “Removing the air lter
unit”.
1) Clean the air filter unit.
f Vacuum dirt and dust from the air lter unit.
f Do not wash the air lter unit.
Attaching the air lter unit
1) Attach the new air filter unit to the air filter cover.
f There is a distinction between the inside and outside of the air lter unit. Align the red mark on the air lter
unit with the red mark on the air lter cover.
Air lter unit
Inside (Smooth bre)
Outside (Cotton-like bre)
Air lter cover
Red mark
f Insert the air lter unit to the side with the two hooks and then press the other side of the air lter unit into
the cover side with one hook.
Hook
Hook
Air lter cover
Air lter unit
Red mark
2) Attach the air filter cover to the projector.
f Perform Step 1) in “Removing the air lter unit” (x page 113) in the reverse order.
f Make sure that the air lter cover is closed tightly.
Resetting the filter counter
Be sure to reset the lter counter after cleaning or replacing the air lter unit.
1) Connect the power plug, press the power <v/b> button.
2) Press the <MENU> button to display the main menu, then press as to select [PROJECTOR SETUP].
3) Press the <ENTER> button, press as to select [FILTER COUNTER].
Chapter 6 Maintenance - Maintenance/replacement