EasyManua.ls Logo

Panasonic PT-VW530

Panasonic PT-VW530
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8 [AV MUTE]
Displays the AV mute status.
9 [VOLUME]
Displays the volume status.
10 [INPUT]
Displays the status of the selected input.
11 [INTAKE AIR TEMPERATURE]
Displays the status of the air intake temperature of the
projector.
12 [EXHAUST AIR TEMPERATURE]
Displays the status of the exhaust air temperature of the
projector.
13 [LAMP RUNTIME]
Displays the runtime of the lamp (converted value).
14 [SELF TEST]
Displays the self diagnostics information.
15 [PROJECTOR RUNTIME]
Displays the runtime of the projector.
Error information page
When [Error (Detail)] or [Warning (Detail)] is displayed in the self-diagnosis display of the [Projector status] screen, click it to
display the error/warning details.
f The projector may go into the standby status to protect the projector depending on the contents of the error.
1
1 Self-diagnosis result display
Displays the item check results.
[OK]: Indicates that operation is normal.
[FAILED]: Indicates that there is a problem.
[WARNING]: Indicates that there is a warning.
r [FAILED] items displayed when a problem occurs
Parameter Description
[FAN] Trouble has occurred in the fan or its drive circuit. Consult your dealer.
[FAN(INTAKE1)] Trouble has occurred in the intake fan 1.
[FAN(INTAKE2)] Trouble has occurred in the intake fan 2.
[FAN(INTAKE3)] Trouble has occurred in the intake fan 3.
[FAN(INTAKE4)] Trouble has occurred in the intake fan 4.
[FAN(EXHAUST)] Trouble has occurred in the exhaust fan.
[FAN(LAMP)] Trouble has occurred in the lamp cooling fan.
[INTAKE AIR TEMPERATURE]
The air intake temperature is too high. The projector may be used in an operating
environment where the temperature is high, such as near a heating appliance.
[EXHAUST AIR TEMPERATURE] The exhaust air temperature is high. The air exhaust port may be blocked.
[LAMP REMAIN TIME]
The lamp runtime has exceeded the prescribed cumulative time, and it is now
time to replace the lamp.
[LAMP STATUS]
The lamp has failed to light.
Wait a short while for the lamp to cool off, and then turn on the power.
[APERTURE (CONTRAST-SHUTTER)] Trouble has occurred in the contrast shutter circuitry. Consult your dealer.
[AIR FILTER]
There is too much dust accumulated in the air lter unit. Turn off the projector
and unplug the power plug from the wall outlet, then replace the air lter unit.