-19-
Mechanical Disassembly
1. Remove the 2 screws-A(T3x12) to remove the speaker holder. Remove the 2
screws-B(T3x8) to remove the speaker(SP901).
2. Loosen 3 screws-C to remove the lamp assy (LP900).
3. Remove 4 screws-D (T3x8) to remove the optical unit.
4. Remove 3 screws-E (T3x8) and 1 screw-F(M3x8) to remove the lamp holder.
Remove 2 screws-G(T3x6) to remove the ID connect board.
5. Remove 2 screws-H(T3x8) to remove the sub power board.
6. Remove 3 screws-K (M3x8) and 1 screw-J (T3x8) to remove the AC filter board.
Fig.3
Optical Unit
F
Lamp assy
(LP900)
C
ID connect board
C
E
B
Speaker holder
B
Speaker
(SP901)
C
D
D
D
D
G
G
H
H
K
K
K
Sub power
board
AC Filter board
Bushes
E
A
A
J
Inside light
shield
Outside
light shield
(T3x8)x2
E
Lamp
holder
Note:
When removing screws-G which is to
fix the ID connect board, the special
screwdriver is needed as the below;
Star screwdriver Size: T10
3. Speaker(SP901), lamp assy(LP900), optical unit removal