-37-
Electrical Adjustments
3. Auto calibration adjustment [Component]
Input mode Computer 1 (Component)
Input signal 480i component signal
Signal pattern 8 color bar
1. Enter the service mode
2. Select Group 260”, No.0 and set the data value
to 1”.
The projector begins auto-calibration and then "OK"
will appear on the screen.
Below adjustments are performed when the above auto
calibration is failed.
Gain adjustment [Component]
Input mode Computer 1 (Component)
Input signal 480i component signal
Signal pattern 16-step gray scale
Equipment Oscilloscope
1. Enter the service mode.
2. Adjust the amplitude aof waveform at each test point
to be minimum by changing the data value of Group
- No.
Group - No. Test Points
0 - 3 TP35G
(a)
White Level
4. Auto calibration adjustment [Video]
Input mode Video
Input signal Composite video signal
Signal pattern 16-step gray scale
1. Enter the service mode.
2. Select Group 260”, No. 0and then change data val-
ue from 0 to 1”. After the auto-calibration completed,
OK will appear on the screen.
Below adjustment is performed when the above auto
calibration is failed.
5. Common center adjustment
Input mode Computer 1 (RGB)
Input signal XGA computer signal
Signal patterns 50% R, G, B whole signals
1. Enter the service mode
2. Select Group “
100”, No.92 and change the data
value to “2 to reduce the panel frequency.
3. Change data value to obtain the minimum flicker for
each color on the screen.
Group - No. Adjustment
101
- 1 for green flicker
101 - 0 for red flicker
101 - 2 for blue flicker
4. Select Group “
100”, No.92 and change the data
value to “0 to reset the panel frequency.
Pedestal adjustment [Component]
Equipment Oscilloscope
1. Enter the service mode.
2. Adjust the black level on each test point to be minimum
by changing the data value of Group - No.
Group - No. Test Points
0 - 0 TP35G
0 - 1 TP35R
0 - 2 TP35B
Black Lebel
Gain adjustment [Vodeo]
Equipment Oscilloscope
1. Enter the service mode.
2. Adjust the amplitude aof waveform at each test point
to be minimum by changing the data value of Group
- No.
Group - No. Test Points
20 - 0 TP35G
(a)
White Level