9.2.27. Remove the Cabinet assy from the
Plasma panel section
1. Remove the Plasma panel section from the servicing
stand and lay on a flat surface such as a table (covered
by a soft cloth) with the Plasma panel surface facing
downward.
2. Remove the screws (×21 ).
3. Remove the Cabinet assy from the Plasma panel section.
9.2.28. Remove the Contact metals
1. Remove the screws (×10 ).
2. Remove the Contact metal side (L, R).
3. Remove the screws (×15 ).
4. Remove the Contact metal bottom.
9.2.29. Remove the C1-Board
1. Disconnect the flexible cables (CB1, CB2, CB3, CB4 and
CB5).
2. Disconnect the flexible cable (C10).
3. Disconnect the connectors (C14 and C18).
4. Remove the screws (×5 ) and remove the C1-Board.
9.2.30. Remove the C2-Board
1. Disconnect the flexible cables (CB6, CB7, CB8, CB9,
CB10 and CB11).
2. Disconnect the flexible cables (C20, C21 and C26).
3. Disconnect the connectors (C25 and C28).
4. Remove the screws (×6 ) and remove the C2-Board.
9.2.31. Remove the C3-Board
1. Disconnect the flexible cables (CB12, CB13, CB14 and
CB15).
2. Disconnect the flexible cables (C31 and C36).
3. Remove the screws (×4 ) and remove the C3-Board.