8.2. Initialization Pulse Adjust
1. Set Aging pattern 0 (Vset ajustment pattern) by IIC mode.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
3. Connect Oscilloscope to TPSC1 (T2) and adjust VR6602 for 190±10µ Sec.
Test point Volume Level
T2 TPSC1 (SC) VR6602 (SC) 190 ± 10µ Sec.
8.3. P.C.B. (Printed Circuit Board) exchange
8.3.1. Caution
1. To remove P.C.B., wait 1 minute after power was off for discharge from electrolysis capacitors.
8.3.2. Quick adjustment after P.C.B. exchange
Adjust the following voltages with the multimeter.
P.C.B. Name Test Point Voltage Volume Remarks
P Board Vsus TPVSUS (SS) Vsus ± 2V R628 (P) *
PFC C446 (+) (-) (P) 396V ± 0.5V R443 (P)
SC Board Vad TPVAD (SC) -105V ± 1V VR6600 (SC)
SS Board Ve TPVE (SS) Ve ± 1V VR6000 (SS) *
D, DS, DN Board White balance, Pedestal and Sub brightness for NTSC, PAL, HD, PC and 625i signals
DN Board Set Market Select Number to correct destination by MS mode. (See chap. 10.1.4)
*See the Panel label.
Caution:
Absolutely do not reduce Vsus voltage below Ve not to damage the P.C.B.
22
TH-42PH10BK / TH-42PH10BS / TH-42PH10EK / TH-42PH10ES