SD Mode
Select the SD mode by Up/Down button on the remote control at the front page of CAT mode and then press
the Action button on the remote control.
To exit the SD mode, press the R button on the remote control.
MS Mode
Select the MS mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute
button on the remote control more than 3 seconds.
To exit the MS mode, press the R button on the remote control.
Caution:
Market Select should be set after exchange of A-Board.
Destination number:
Number Destination
0 Japan
1 US(North America)
2 Europe
3 Asia,
Oceania,ME,Africa
18 China
Input command
check
MTBF Parameter WT PT
TE
Condition
Sensor
SD
History of remote control command.
(Factory use).
Cumulative Time for power on condition. (unit :hour)
Temperature (unit :degrees)
OSD
** ** ** ** ** ** **
** ** ** ** ** ** **
** ** ** ** ** **
**
**
+**
Counter of power on. (unit :time)
Market select **.** 2 2
MS
Change by Left/Right buttons on the
remote control and press the action button
Present number
EEPROM data version
---
Illumination sensor value
*
Counter of backlight OFF during abnormally high temperature(unit:time)
***
BL
Backlight Limit Value
Remote Control Mode A B