DigiplexNE DGP-NE96 - 30 - Programming Guide
= De fault se tting
Dialer Options
= De fault se tting
SECTION [3032] : Partition Options 2 SECTION [3033] : System Options 2
Option OFF ON Option OF F ON
[1] Be ll/sire n output in par tit ion 1 N Disabled Enabled [1] Multiple a ction s in user m enu Disabled N En able d
[2] Be ll/sire n output in par tit ion 2 Disa bled N En abled [2] User cod e leng th Fi xed N Fl e x ib l e
[3] Be ll/sire n output in par tit ion 3 Disa bled N Enab led [3] User cod e leng th (if option [2 ] OFF) 4-digits N 6-digits
[4] Be ll/sire n output in par tit ion 4 Disa bled N En abled [4] Power save mode N Disabled Enable d
[5]
Be ll/sire n output in par tit ion 5 Disa bled N En abled
[5]
Bypass not displayed while system
is armed
N Disabled Enable d
[6] Be ll/sire n output in par tit ion 6 Disa bled N En abled [6] Tro uble L atch Disabled N Enabled
[7] Be ll/sire n output in par tit ion 7 Disa bled N En abled [7] EOL r esistor on h ardwire zon es Disabled N Enabled
[8] Be ll/sire n output in par tit ion 8 Disa bled N En abled [8] (ATZ) Zone Doubling Disabled N Enabled
SECTION [3034] : System Options 3 SECTION [3035] : Restrict Arming Options
Option OFF ON Option OF F ON
[1]&[2] Wireless Tr ansmitt er S upe rvisio n
Options (see table below)
N
See Tabl e
N
See Tabl e
N
See Table
N
See Table
[1] Restr ict arming on A C fa ilure Disabled N Enabled
[2]
Restr ict arming on b atter y failure
Disabled
N Enabled
[3]
Generate super visio n fail ur e if
dete cted on a bypassed wi reless zo ne
Yes N No [3] Restrict arming on b ell o r auxiliary
failure
Disabled N Enabled
[4] Restrict arming on a wireless
transmitter supervision failure
Disa bled
N Enab led [4] Restrict ar ming on TLM failur e
Disabled
N Enabled
[5]&[6] Zon e & Modu le Tamper Recog nition
Options (see table below)
N
See Tabl e
N
See Tabl e
N
See Table
N
See Table
[5] Restr ict arming on mod ule troubles Disabled N Enabled
[6] Future Use N N/A N N/ A
[7] Ge ner ate tamper if dete cted o n
byp ass zone
NYes No [7] Tra nsmit zon e statu s on se rial po rt Disabled N Enabled
[8]
Restrict a rmin g o n tamper troub le Disa bled N En abled
[8] Serial P ort Baud Rate
1 9, 200
N 38, 40 0
Wireless Transmitter Supervision Options
(Section [3034]; options [1] & [2])
Zone & Mo du le Tamper Reco gn iti on Op tio ns
(Section [303 4]: opt io ns [5 ] & [6 ])
[1] [2] [5] [6]
OFF O FF - Disabled (def au lt ) OFF O FF - Disa bled (default)
ON OFF - When disarmed: GENERATES TROUBLE ONLY ON O FF - When disa rmed : G E NE RAT E S TROUBLE ONLY
- When armed: Follows Zone Alarm Types (page 7) - Wh en arm ed : Follows Zo ne Alarm Typ es (page 7)
OFF ON - When disarmed: GENERATES SILE NT ALARM OFF O N - Wh en disa rmed : G E NE RAT E S SILENT ALARM
- When armed: Follows Zone Alarm Types (page 7) - Wh en arm ed : Follows Zo ne Alarm Typ es (page 7)
ON ON - When disarmed: GENERATES AUDIBL E ALARM ON O N - Wh en disa rmed : G E NE RAT E S AUDIBLE AL ARM
- When armed: Follows Zone Alarm Types (page 7) - Wh en arm ed : Follows Zo ne Alarm Typ es (page 7)
SECTION [3036]: Dialer Options 1 SECTION [3037] : Dialer Options 2
Option OFF ON Option OF F ON
[1]&[2]
Telephone Line Monitoring (TLM) -
(see ta ble on page 29 )
N
See Table
N
See Table
N
See Table
N
See Table
[1] Call back Disabled N Enabled
[2] Automatic eve nt buffer transmission Disabled N Ena bled
[3] Dia ler ( re por ting to monitoring
station)
Disa bled
NEnabled [3 ]& [ 4] Hourly test t ransmissio n (see table
on pa ge 29)
N
See Table
N
See Table
N
See Ta ble
N
See Ta ble
[4] Dialing method N Pu lse
Tone
(DTMF)
[5]
Pulse ratio
(E.U. = Europe ; N. A. = Nort h Ame rica)
N 1: 2 (E.U.)
1:1.5
(N.A.)
[5] Keypad beep on successful arming/
disa rming repo rt
Disabled
N Enabled
[6] Bu sy tone detectio n N Disabled Enabled [6] Alte rnate Dialing Disabled N En able d
[7]
Switch to p ulse dialing o n 5
th
attempt
Disa bled N En abled [7] Dial Ton e Delay (if n o dial to ne)
Force dial
N Ha ng -u p
[8]
Be ll/sire n upon co mmunication
failure if system is armed
Disa bled N En abled [8] Rep or t zone restor e
ON = On zone closure; OFF = On b ell c u t- o ff
Disabled N Enabled