DigiplexNE DGP-NE96 - 31 - Programming Guide
Other Options
SCHEDULE TOLERANCE WINDOW
Tel ephone L in e Monito ri ng (TLM) Optio ns
(Section [3036]; options [1] & [2])
Hourly Test Transmission Options
(Section [303 7]: opt io ns [3 ] & [4 ])
[1] [2] [3] [4]
OFF
OFF
ON
ON
OFF
ON
OFF
ON
Disabled (default)
When armed: GENERATES AN AU DIBL E ALARM
When armed: GENERATES A TROUBLE
TL M sile nt a larm: BE COM ES AN AUDIBL E ALAR M
OFF O FF Transmit the test report code everytime the days programmed
in section [3040] have elapsed at the time programmed in
section [ 30 41] . (de fau lt)
ON O N When disarmed: Transmit test report code everytime the time
prog r ammed in sect ion [ 30 43] ha s ela psed .
When armed: Transmit test report code everytime the time
prog r ammed in sect ion [ 30 42] ha s ela psed .
ON OFF The control panel will transmit the test report code everytime
th e m inu tes prog ra mmed in se ction [3 04 1] (t he last two digits)
ha ve e lapse d.
Se ction Da ta Des cri ption Defaul t
[303 9] __/ __ /__ ( x 1 min ute ) S CHEDULE TOLERANCE WINDOW 00 0
AUTO TEST REPORT SETTINGS
Se ction Da ta Des cri ption Defaul t
[304 0] __/ __ /__ ( x 1 da y; 0 00 = disab le d) A UT O TE ST REPOR T 00 0
[304 1] __/ __ : _ _/_ _ Hrs ( 00 -2 3) & Min s (00- 59 ) A UTO TE S T R EPOR T TIME OF DAY 00 : 00
[304 2] __/ __ /__ (00 0 - 2 55 x 1 minu te) A RM ED RE PO R T DE LAY 5 minute s
[304 3] __/ __ /__ (00 0 - 2 55 x 1 minu te) DISARM ED REP O RT DELAY 60 minu tes
TIMI NG S
Se ction Da ta Des cri ption Defaul t
[305 0] __/ __ /__ (00 1 - 1 25, 12 8 - 253; 0 00 = Disa bled)
Addi ng Va lue s: 00 1 to 125 = [ val ue] x [.008 ] (+ 0.008 t o 1 sec. )
Subtract in g Val ues: 128 t o 25 3 = [value] - [127 ] x [- . 00 8] (-0 .0 08 to -1. 008 se c.)
CLOCK COMPENSA TION VAL UE Disa bled
[305 1] __/ __ /__ (00 0 - 2 55) RING COUNTER 00 8
[305 2] __/ __ /__ (00 0 - 2 55 x 4 secon ds) A NSWERING MACHINE OVERRIDE DEL AY 32 seconds
[305 3] __/ __ /__ (00 0 - 2 55 x 2 secon ds) TL M FAIL TIMER 32 seconds
[305 4] __/ __ /__ (00 0 - 1 27 x 1 secon d) DELAY BETWE EN DIAL ING ATTEMPTS 20 seconds
[305 5] __/ __ /__ (00 0 - 2 55 x 1 secon d; 00 0 = In stan t Re port) DELAY ALAR M TRANS MISSION TIMER 000
[305 6] __/ __ /__ (00 0 - 2 55 x 1 atte mpt) MAX IM UM DIALING ATTEMPTS 8 attempts
= Default setting
SECTION [3038]: Access Control Options
Opti on OFF ON
[1 ] Access control feature Disabled N Enable d
[2 ]
Log “Req uest fo r Exit” in eve nt
buff er*
Disabled N Enable d
[3 ]
Log “Doo r Left Op en Resto re ” in
even t buff er
Disabled N Enable d
[4 ]
Log “Doo r Forced Resto re ” in e vent
buff er
Disabled N Enable d
[5 ] Burglar alarm o n for ced doo r Disabled N Enabled
[6 ]
Skip ex i t de la y whe n a rm in g w ith
access card
Disabled N En abled
[7 ] Burglar alarm o n do or left op en Disabled N Ena ble d
[8 ] Who has access during clock loss All users N Masters
* Since “Request for Exit” events can occur often, the Event
Buffe r ma y fill up quickly.