DigiplexNE DGP-NE96 - 37 - Programming Guide
PARTITION PANIC ALARM OPTIONS
PARTITION BELL SQUAWK OPTIONS
PARTITION ONE-TOUCH OPTIONS
* If a ke ypad i s a ssi gne d to m or e t han one pa rt iti on, the one-touc h fe ature mus t be ena bled i n all the ke ypads assigne d part itions. Example: To enable the one-touch Regular Arming
feature of a keypad assigned to partitions 1, 2 and 5, enable sections [3125] option [1], [3225] option [1] and [3525] option [1].
Partition 1
[3123]
Partition 2
[322 3]
Partition 3
[332 3]
Partition 4
[3423]
Partition 5
[352 3]
Partition 6
[362 3]
Partition 7
[3723]
Partition 8
[382 3]
Option ( = Default Setting) OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON
[1] Panic 1 (Keys 1 & 3) N N N N N N N N
[2] Panic 2 (Keys 4 & 6) N N N N N N N N
[3] Panic 3 (Keys 7 & 9) N N N N N N N N
[4] Panic 1 Alarm Type (OFF = Report Only; ON = Au dib le Ala rm)
N
N
N
N
N
N
N
N
[5] Panic 2 Alarm Type (OFF = Report Only; ON = Au dib le Ala rm)
N
N
N
N
N
N
N
N
[6] Panic 3 Alarm Type (OFF = Report Only; ON = Fire Alarm)
N
N
N
N
N
N
N
N
[7] Report Disarming Options (OFF = Alwa ys; ON = Onl y A f te r Alar m )
N
N
N
N
N
N
N
N
[8] Future Use N/ A N/A N/A N/A N/A N/A N/ A N/ A N/A N/A N/A N/A N/A N/ A N/A N/A
Partition 1
[3124]
Partition 2
[322 4]
Partition 3
[332 4]
Partition 4
[3424]
Partition 5
[352 4]
Partition 6
[362 4]
Partition 7
[3724]
Partition 8
[382 4]
Option ( = Default Setting) OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON
[1] Bell Squawk upon Disarming N
N
N
N
N
N
N
N
[2] Bell Squawk upon Arming N N N N N N N N
[3] Bell Squawk upon Aut o-a rmin g N N
N
N
N
N
N
N
[4] Bell Squawk during Exit Delay N
N
N
N
N
N
N
N
[5] Bell Squawk during Entry Delay N
N
N
N
N
N
N
N
[6] Bell Squawk upon Remote Arming/Disarming N
N
N
N
N
N
N
N
[7] Ring Back: Be ll Sq uawk if Disar med a fter Alarm
N
N
N
N
N
N
N
N
[8] Ring Back: Ke ypad bee ps if Disarme d aft er Ala rm
N
N
N
N
N
N
N
N
Partition 1
[3125]
Partition 2
[322 5]
Partition 3
[332 5]
Partition 4
[3425]
Partition 5
[3 525 ]
Partition 6
[362 5]
Partition 7
[3725]
Partition 8
[3 825 ]
Option ( = Default Setting) OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON
[1] One- tou ch Regu lar A rmin g*
N
N
N
N
N
N
N
N
[2] One- tou ch Stay A rming* N N N N N N N N
[3] One-tou ch Instant Arming *
N
N
N
N
N
N
N
N
[4] One- tou ch Force Arming *
N
N
N
N
N
N
N
N
[5] One- tou ch Stay o r In stant Disarming *
N
N
N
N
N
N
N
N
[6] One- tou ch Bypa ss Programming*
N
N
N
N
N
N
N
N
[7] One- tou ch Even t Disp lay*
N
N
N
N
N
N
N
N
[8] No Exit De la y wh en A rm in g w it h r emo te con tro l
N
N
N
N
N
N
N
N

Related product manuals