26 Reference & Installation Manual
7.1.11 Instant Fire Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 11
when a Instant Fire zone opens, whether it is armed or disarmed, the control panel will send the corresponding Alarm
Report Code and the alarm is always audible regardless of other settings. Fire alarms generate an intermittent (pulsed)
bell/siren output signal as shown in Figure 9 on page 26.
Figure 9: Bell/Siren Output during a Fire Alarm
7.1.12 Delayed Fire Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 12
When a Delayed 24Hr. Fire zone opens, whether it is armed or
disarmed, the control panel will react as shown in Figure 10.
Delayed 24Hr. Fire zones are commonly used in residential homes
where a smoke detector often generates false alarms (i.e., burning
bread, etc.). Fire alarms generate an intermittent (pulsed) bell/siren
output signal as shown in Figure 9 above.
7.1.13 Instant Fire Silent Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 13
When a Instant Fire Silent zone opens, whether it is armed or
disarmed, the control panel will generate the following:
The control panel can send the corresponding Alarm Report Code
and the alarm will be silent regardless of other settings.
7.1.14 Delayed Fire Silent Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 14
When a Delayed Fire zone opens, whether it is armed or disarmed,
the control panel will react as shown in Figure 10. Delayed 24Hr.
Fire zones are commonly used in residential homes where a
smoke detector often generates false alarms (i.e., burning bread,
etc.). The control panel can send the corresponding Alarm Report
Code and the alarm will be silent regardless of other settings.
7.1.15 24 Hr. Buzzer Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 15
When a 24Hr Buzzer Zone opens, whether the zone is armed or
disarmed, the control panel sets off the keypad’s buzzers to
indicate that the zone was breached. The control panel will report
the alarm, but will not enable the bell/siren output. Enter any valid
access code on the keypad to stop the buzzer. This zone definition
is particularly useful when a user wishes to be notified when
something such as a safe or locker within the home has been
accessed (i.e. a child accessing a valuable collection).
7.1.16 24 Hr. Burglary Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 16
when a 24Hr Burglary Zone opens, whether the system is armed or disarmed, the control panel will immediately
generate an alarm. This alarm is defined by the alarm type, configured in Zone Programming under zone options [4]
and [5]. See Alarm Types on page 29.
Figure 10: Delayed 24Hr Fire Zone

Table of Contents

Other manuals for Paradox Spectra SP4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra SP4000 and is the answer not in the manual?

Paradox Spectra SP4000 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256 events
StayD ModeYes
Expandable via Expansion ModulesYes
BusYes, 4-wire expansion bus
Battery Backup12V 7Ah
PGM Outputs2

Related product manuals