Magellan / Spectra SP 27
7.1.17 24 Hr. Hold-up Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 17
When a 24Hr. Hold-up zone opens, whether it is armed or disarmed, the control panel will immediately generate an
alarm. This alarm is defined by the alarm type, configured in Zone Programming under zone options [4] and [5]. See
Alarm Types on page 29. The SIA FSK and CID reporting formats include specific report codes to identify the alarm as
a Hold-up alarm.
7.1.18 24 Hr. Gas Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 18
When a 24Hr. Gas zone opens, whether it is armed or disarmed, the control panel will immediately generate an alarm.
This alarm is defined by the alarm type, configured in Zone Programming under zone options [4] and [5]. See Alarm
Types on page 29. The SIA FSK and CID reporting formats include specific report codes to identify the alarm as a Gas
alarm.
7.1.19 24 Hr. Heat Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 19
When a 24Hr. Heat zone opens, whether it is armed or disarmed, the control panel will immediately generate an alarm.
This alarm is defined by the alarm type, configured in Zone Programming under zone options [4] and [5]. See Alarm
Types on page 29. The SIA FSK and CID reporting formats include specific report codes to identify the alarm as a Heat
alarm.
7.1.20 24 Hr. Water Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 20
When a 24Hr. Water zone opens, whether it is armed or disarmed, the control panel will immediately generate an
alarm. This alarm is defined by the alarm type, configured in Zone Programming under zone options [4] and [5]. See
Alarm Types on page 29. The SIA FSK and CID reporting formats include specific report codes to identify the alarm as
a Water alarm.
7.1.21 24 Hr. Freeze Zones
Sections [001] to [032]: Zones 1 to 32, First Digits = 21
When a 24Hr. Freeze zone opens, whether it is armed or disarmed, the control panel will immediately generate an
alarm. This alarm is defined by the alarm type, configured in Zone Programming under zone options [4] and [5]. See
Alarm Types on page 29. The SIA FSK and CID reporting formats include specific report codes to identify the alarm as
a Freeze alarm.
7.1.22 24Hr. Panic
Sections [001] to [032]: Zones 1 to 32, First Digits = 22
When a 24Hr. Panic zone opens, whether it is armed or disarmed, the system will immediately generate an alarm. This
alarm is defined by the panic options set in section [702]. The SIA FSK and CID reporting formats include specific
report codes to identify the alarm as a Panic alarm. Section [702] option [1] (Panic 1) must be enabled for the 24Hr.
Panic zone to function.
7.1.23 Instant No Pre-Alarm
Sections [001] to [032]: Zones 1 to 32, First Digits = 23
This zone definition ignores the Flex-Instant delay, and acts like a traditional Instant zone.
7.1.24 Follow No Pre-Alarm
Sections [001] to [032]: Zones 1 to 32, First Digits = 24
This zone definition ignores the Flex-Instant delay, and acts like a traditional Follow zone.

Table of Contents

Other manuals for Paradox Spectra SP4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra SP4000 and is the answer not in the manual?

Paradox Spectra SP4000 Specifications

General IconGeneral
Partitions2
User Codes32
Event Buffer256 events
StayD ModeYes
Expandable via Expansion ModulesYes
BusYes, 4-wire expansion bus
Battery Backup12V 7Ah
PGM Outputs2