Configuration
Configuration header. This mode is used for changing the clock format, selecting stagger up,
setting the lengths of the 4 durations and for programming the on/off times of the 4 duty
cycle patterns. Use the NEXT key to begin programming.
Select 12 hour or 24 hour clock format using the +/- key.
Select the stagger up time between channels. This stagger up occurs after a power out-
age and after a status update. This screen only appears with an EL72 using maintained
relays. The following stagger up selections are available:
NO = not used 01.00 = 1 minute
00.05 = 5 seconds 05.00 = 5 minutes
00.15 = 15 seconds 10.00 = 10 minutes
00.30 = 30 seconds 15.00 = 15 minutes
Programs the duration length for dUR1-dUR4, which are event types (see Events). These
durations are programmable from 1 second to 23 hours, 59 minutes and 59 seconds. The
control will not allow a duration of 0:00.00.