6.6 Filters Maintenance
Before installing a new filter cartridge, clean very carefully the filter housing, of all liquids.
PARAMINA compressors operate at environmental temperatures from +5
0
C to +45
0
C. Higher
temperatures could cause changes in the quality of breathing air; lower temperatures may cause a
malfunction.
CAUTION: Before any interference in the filters’ housing, make sure there is no compressed air inside
and that all drain valves have been opened manually.
Maintenance work on the compressor must always be done with the compressor stopped and
disconnected from the mains supply.
Filters’ housing lifetime is 20 years. Hydraulic overpressure test, every 5 years.
Option 1 (standard version till end of 2017):
Ø90 x 770 (max. working pressure 350 bar)
Replacement of active carbon - molecular sieve cartridges
1. Unscrew the filter head counter clockwise.
2. Remove the filter head and the spring.
3. Place the special handle on top of the A.C.-M.S cartridges.
4. Remove the A.C.-M.S. cartridges by pulling upwards with the special handle. Before throwing away the
used cartridges, do not forget to remove the cartridge connector.
5. Clean the inside of the filter housing with a clean cloth.