User Manual - Cyclone Silent - 1-2018 edition
PARAMINA SA – Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860-1
Fax: 0030 210 5575868, email: service@paramina.gr - website: www.paramina-compressors.com
44
6.9 Maintenance Calendar
Operating Hours
Check V - Belt tension
Change oil
Change Air Filter
Change Coalescing pre-filter
Change BA filter
Check Valves
Pistons and piston rings
Date
Sign
Every Day Check: the general condition of the compressor, Oil Level, all connections for leakage, for
unconventional operation, the auto drains and the color of condensates
1. We recommend you to calibrate compressors manometers each year or according to:
a. Compressor’s yearly operation hours.
b. The application in which compressor operates.
2. Interstage & Final stage condensate separator lifetime is 20 years. Hydraulic Overpressure test, every 5
years.
3. BA Filter’s housing lifetime is 20 years. Hydraulic Overpressure test, every 5 years.