46
8.Wrong cable diameter or long cable
8.Check - Replace
9.Interstage safety valves leaking
9.Check - Replace
Compressor does not
attain final pressure
1.Condensate drain Valve and / or fittings
leaking
1.Tighten and reseal
2.Premature opening of final safety valve
2.Clean final safety valve and readjust
3. Excessive piston clearance
3. Replace and regulate again
4. Final Safety valve’s safety lock opens
prematurely
4. Check the intermediate pressures,
regulate or replace valves
5.Interstage safety valves leaking
5.Check - Replace
6.Final stage piston rings worn
9.Check - Replace
Safety valves between
individual stages
releasing pressure
1.If the 1
st
stage safety valve is released,
the 2
nd
stage valves do not close properly.
1.Check replace valves
2.If the 2
nd
stage safety is released, the 3
rd
stage valves do not close properly.
2.Check replace valves
3.Stacked 4
th
stage piston
3.Replace
4. Blocked Sintered Filter of 3
rd
stage
separator (when 2
nd
stage safety valve
opens)*
4.Clean or Replace
5. Blocked Sintered Filter of 4
th
final
stage separator (when 3
rd
stage safety
valve opens)*
5.Clean or Replace
Compressor runs too
hot
1.Insufficient supply of fresh cooling air
1.Check location. Check inlet air
suction. Max. ambient temperature
under 45 ºC
2.Intake or outlet valves are not closing
properly
2.Check and clean valves, Replace if
necessary
3.Wrong direction of rotation
3.See arrow on the compressor and
remedy accordingly
4.Low oil level
4.Check oil level
Oil residue/Oil smell in
delivered air
1.Improper maintenance of final filter
1.Service filter - Renew BA cartridge
2.Wrong type of oil
2.Use right type of oil
3.Activated carbon saturated
3.Renew BA cartridge
4.1
st
, 2
nd
, or 3
rd
stage piston rings worn
4. Check - Replace
5. Worn Cylinders
5. Check - Replace
* Concerns only compressors equipped with separators part numbers 208501600, 208501610, 208501620 &