EasyManuals Logo

Paramina MISTRAL M6-EM User Manual

Default Icon
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
User Manual - Mistral M6&M8 - 04-2018 from s.n.1882761 edition
.
PARAMINA SA Byway Evaggelistrias str. 19300 Aspropirgos, Greece, Tel: 0030 210 5575860
Fax: 0030 210 5575868, email: service@paramina.gr - website: www.paramina-compressors.com
29
pressure
2.If the 2
nd
stage safety valve is released,
the 3
rd
stage valves do not close properly
2.Check replace valves
3. 2
nd
or 3
rd
stage piston stuck
3.Replace
4. Blocked Sintered Filter of 2
nd
stage
separator (when 1
st
stage safety valve
opens)*
4.Clean or Replace
5. Blocked Sintered Filter of 3
rd
final
stage separator (when 2
nd
stage safety
valve opens)*
5.Clean or Replace
Compressor runs too
hot
1.Insufficient supply of fresh cooling air
1. Check location. Max Ambient
temperature under 40 ºC
2.Intake or outlet valves are not closing
properly
2.Check and clean valves, Replace if
necessary
3.Wrong direction of rotation
3.See arrow on the compressor and
remedy accordingly
4.Low oil level
4.Check oil level
Oil residue/Oil smell in
delivered air
1.Improper maintenance of final filter
1.Service filter - Renew BA cartridge
2.Wrong type of oil
2.Use right type of oil
3.Activated carbon saturated
3.Renew BA cartridge
4.1
st
, 2
nd
, or 3
rd
stage piston rings worn
4. Check - Replace
5. Worn Cylinders
5. Check - Replace
* Concerns only compressors equipped with separators part numbers 208501600, 208501610, 208501620 &
208704200.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paramina MISTRAL M6-EM and is the answer not in the manual?

Paramina MISTRAL M6-EM Specifications

General IconGeneral
BrandParamina
ModelMISTRAL M6-EM
CategoryAir Compressor
LanguageEnglish

Related product manuals