Replacement of active carbon - molecular sieve cartridge / coalescing cartridge
PARAMINA compressors operate at environmental temperatures from -5
0
C to +45
0
C.
Higher temperatures could cause changes in the quality of breathing air; lower
temperatures may cause a malfunction.
CAUTION: Before any interference in the filter’s housing, make sure there is not inside air
under pressure.
Maintenance work on the compressor must always be done with the compressor stopped
and disconnected from the mains supply.
Filter’s housing lifetime is 20 years. Hydraulic Overpressure test, every 5 years.
1. Unscrew the filter housing by hand and remove it from its base.
2. Unscrew the A.C.-M.S. cartridge from the cartridge connector. Place and hold a wrench on the
cartridge connector while unscrewing the cartridge.
3. Lay a small amount of silicone grease on the o-ring of the filter’s base. If there is a trace of
damage on the o-ring, replace.
4. Remove the new A.C.-M.S. cartridge from its protective case. If the packaging is damaged or
punctured do not use it.
5. Lay a small amount of silicone grease on the o-ring of the new A.C.-M.S. cartridge.
6. Screw the new cartridge on the cartridge connector.
7. Clean the inside of the filter housing with a clean cloth.
8. Screw the filter housing carefully until securely fastened onto the base.
Active carbon molecular sieve cartridge replacement