1. Unscrew the filter housing by hand and remove it from its base.
2. Unscrew the A.C.-M.S. cartridge along with its connector (cartridge connector) from the tube
connector.
3. Remove the coalescing cartridge from the filter’s base by pulling upwards.
4. Lay a small amount of silicone grease on the o-ring of the filter’s base. If there is a trace of
damage on the o-ring, replace.
5. Install the new coalescing cartridge on filter’s base by fastening it down with your hand.
6. Wrap a small amount of Teflon around the thread of the tube connector.
7. Screw the cartridge connector on the tube connector (on top of the coalescing cartridge).
9. Remove the new A.C.-M.S. cartridge from its protective case. If the packaging is damaged or
punctured do not use it.
8. Lay a small amount of silicone grease on the o-ring of the new A.C.-M.S. cartridge.
9. Screw the new cartridge on the cartridge connector.
10. Clean the inside of the filter housing with a clean cloth.
11. Screw the filter housing carefully until securely fastened onto the base.
Do not screw really tight, while screwing cartridges or connectors inside filter’s housing.
Active carbon – molecular sieve & coalescing cartridge replacement