Parameter Reference 15-7
AC10 Inverter
Function
Code
Function
Definition
Setting Range
Mfr’s Value
Change
F316
DI1 terminal function setting
0: No function
1: Run
2: Stop
3: Multi-stage speed 1
4: Multi-stage speed 2
5: Multi-stage speed 3
6: Multi-stage speed 4
7: Reset
8: Free stop (coast stop)
9: External coast stop
10: Acceleration/deceleration hold
11: Forward run jogging
12: Reverse run jogging
13: Increase frequency UP
14: Decrease frequency DOWN
15: “FWD” terminal
16: “REV” terminal
17: Three-line type input “X” terminal
18: Accel/decel time switchover 1
19: Reserved
20: Reserved
21: Frequency source switchover
32: Fire control switchover
33: Emergency fire control
34: Accel / decel switchover 2
37: Normally-open PTC motor
temperature protection
38: Normally-closed PTC motor
temperature protection
48: High-frequency switchover
52: Jogging (no direction)
53: Watchdog
54: Frequency reset
55: Manual / auto switchover
56: Manual running
57: Auto running
58: Direction
11
F317
DI2 terminal function setting
9
F318
DI3 terminal function setting
15
F319
DI4 terminal function setting
16
F320
DI5 terminal function setting
7
F321
DI6 terminal function setting
8
F322
DI7 terminal function setting
0
F323
DI8 terminal function setting
0
F324
Free stop terminal logic
0: positive logic (valid for low level);
1: negative logic (valid for high
level)
0
F325
External coast stop terminal logic
0
F326
Watchdog time
0.0~3000.0
10.0
F327
Stop mode
0: Free stop
1: Deceleration to stop
0
F328
Terminal filter times
1100
10
F329
Reserved
F330
Diagnostics of DIX terminal
F331
Monitoring AI1
F332
Monitoring AI2
F335
Relay output simulation
Setting range:
0Output true
1Output false
0
F336
DO1 output simulation
0
F338
AO1 output simulation
Setting range: 04095
0