Bulletin HY25-1135-M1/US
Owner’s Manual
Parker Hannifin Corporation
Chelsea Products Division
Olive Branch, MS 38654 USA
18
Wire Shift PTO
6 and 8-Bolt PTOs
6. Determine from which direction the cable must come in order for the unit to be disengaged when
the knob is all the way in.
NOTE: The shifter must always be installed in the following manner:
CABLE IN: PTO DISENGAGED [6A]: OUT OF GEAR POSITION
CABLE OUT: PTO ENGAGED [6B]: IN GEAR POSITION
7. Install the wire control bracket found in either the 328380X or 328380-1X wire control parts bag. [7]
8. Line the cable up with the wire control bracket and shifter lever (disengaged position) on the PTO
cover assembly. [8]
NOTE: It may be necessary to change the position of the shifter lever on the PTO To do this, remove
the shifter cover from the unit. This will prevent the possible loss of the poppet and/or spring into the
transmission if the shifter post assembly should be pushed through the cover when reinstalling the lever.
9. Shift the PTO to the engaged position to see how much of the cable casing must be cut to
allow the lever enough travel to shift in and out completely. The casing need only go just beyond the
bracket, whereas, the wire must be long enough to go through the swivel pin in the shifter lever. [9]
NOTE: In some instances the cable control may not be long enough. Chelsea has available four longer
lengths than the standard ten-foot cable. These come in five foot increments (i.e., 328346-15X = 15-foot
cable).
10. When the length of the casing has been determined, pull the wire back through until the case can
be cut without cutting the wire. Use a hacksaw or heavy pair of side cutters to cut the casing.
NOTE: The cable can be held by a bench vise as long as the jaws are not tightened to the point where
the case mushrooms. If a vise is not accessible, a pair of vise grips will do the job.
Cable Control Installation Instructions* (Continued)
*All six bolt wire shifts with the exception of the reversible, dual shift units, and some gear boxes.
328346-10X Wire Control Cable
Shift Assembly
Dash Wall or Optional Floor Location
6A
2
6B