DOC-0017-07-EN: AC20 Series - EtherCAT Option
38 (58) DOC-0017-07-EN-B 04.04.2023
Add EtherCAT Slave
Check the target system and the state
Target system should be in Config mode for system setting.
Config Process Data Mapping
Option 1: Using AC20 Input and output mapping tables
The parameter 2566 MASTERMAPPING must be set to FALSE to prevent the PLC from
overwriting the mapping.
Through the mapping tables from the keypad, DSE Lite or Webserver, add parameter numbers
into the appropriate table.
Note: If the first row of a table (input mapping or Output mapping) is empty or equal to 0, the table
will not be accessible and configurable from PLC.