Pilot Operated Prop. DC Valve with VCD
®
Series D*1FP/FE Explosion Proof
Operation Manual
Parker Hannifin Corporation
MSG11-5715-718 D_1FP IECEX UK.indd 19.12.19
Position of the terminal strips
1)
Do not connect with supply voltage zero.
2)
Can be connected to power supply, if no separate enable signal is required.
3)
Reference B12 for diagnostic signal A12.
4)
Provides 24 V signal when no error is detected by the valve electronics, provides 0 V when an error is detected.
5)
Reference for diagnostic A8.
6)
Reference B11 for command signal A9.
7)
Special functions are not shown in the block diagram.
Terminal
strip
Function Terminal Signal in/out
14 pin
Power
supply
A1 PE
A3 +Supply (22...30 V)
A5 0 V Supply voltage
A7 Enable (5...30 V)
2)
Command
signal
A9 Command signal
A11 Command reference
Diagnostic
signal
3)
A8 Diagnostic (voltage ±10 V)
A10 Valve OK output signal
4)
A12
Diagnostic (current 4...20 mA)
Sensor
supply
A2 PE
A4 +Sensor supply
7)
A6
0 V Sensor supply voltage /
reference
5)
Not used
A13 n. c.
A14 n. c.
Terminal
strip
Function Terminal Signal in/out
12 pin
Axis
control
B9 Feedback IN (4...20 mA)
7)
B11
Feedback
reference IN
(4...20 mA)
6) 7)
B10 Feedback IN (±10 V)
7)
B12
Feedback reference IN (±10
V) / Diagnostic reference
3)
BUS
interface
B2 BUS 1
B4 BUS 2
B6 BUS 3
B8 BUS 4
B1 BUS 5
B3 BUS 6
B5 BUS 7
B7 BUS 8
Supplement for valves with EtherCAT interface
please refer to bulletin HY11-5715-708/UK.