If your RSLogic 5000 is Version 13.X:
•Highlightthe1738-ACNR under I/O configuration, right click and
select NewModule.
•ChoosetheGeneric 1738 module from the list of Allen-Bradley
modules.
•Enter a name (optional), an appropriate slot number and the
connection parameters as shown in this screen capture.
•ChooseNext to set RPI.
•ChooseFinish. Notice that the 32 Point Valve Driver Module is
now under the I/O configuration.
Step4: DownloadtheProgramtotheControllerand
CongurethePSSCCNAor1738-ACNRAdapter.
•Reference pages 4-11 through 4-15 of Rockwell publication
1734-UM008 for similar setup procedure.
Step5: ScheduleI/OModuleConnections
•Reference pages 4-15 through 4-19 of Rockwell publication
1734-UM008 for similar setup procedure.
Step6: AccessModuleDataviathePSSCCNAor1738-ACNR
Adapter.
•Makesurethe32outputsofPSSV32AappearinControllerTags.
Use the information in the ladder logic program to access module
data.
•Referencepages4-19through4-22ofRockwellpublication
1734-UM008 for similar information.
Setupthe32PointValveDriverinEtherNet/IP
Step1: Load32PointValveDriverEDSletoRSLinx
•DownloadEDSlefromwww.parker.com/pneu/hserieseldbus
• Onyourcomputer,followStart➔RockwellSoftware➔RSLinx
Tools➔EDSHardwareInstallationTool to load the EDS file to
RSLinx
Step2: SetIPAddressforEtherNet/IPScannerandAdapter
•Set IP address using Rockwell BootP/DHCP utility for
EtherNet/IP scanner and PSSCENA or 1738-AENT adapter.
Reference pages 3-7 through 3-10 of Rockwell publication
1734-UM011 (follow www.rockwell.com➔Support➔Support
Overview➔Online manuals and literature➔I/O➔1734 POINT
and 1734D POINT Block I/O and find POINT I/O Ethernet
Adapter User Manual) for similar information.
Step3: AddEtherNet/IPScannerandAdaptertoRSLogix
5000I/Oconguration.
•AddEtherNet/IPscannerandPSSCENAor1738-AENTadapter
to I/O configuration. Reference pages 4-4 to 4-8 of Rockwell
publication 1734-UM011 for similar information.
Step4: Add32PointValveDrivertoRSLogix5000
I/OConguration.
If your RSLogic 5000 is Version 15.X or greater:
•HighlightthePSSCENA under I/O configuration, right click and
select NewModule.
•ChoosethePSSV32A module from the list of Parker modules.
•Enteraname(optional)andclickOK.
Notice that the 32 Point Valve Drive Module is now under I/O
Configuration.
H Series Fieldbus 32 Point Valve Driver, Series A (PSSV32A) E100P
5